HYDROTHANE HP is a solvent-free, two-component pure polyurea coating, designed for spray-applied, instant-curing waterproofing applications. It forms a flexible, seamless, hard-wearing membrane across simple and complex surfaces with excellent adhesion to concrete, steel, aluminum, plastics, fibers, wood, and foam. HYDROTHANE HP delivers outstanding abrasion, impact, and chemical resistance, maintaining excellent mechanical properties even under extreme climatic conditions. It is VOC-free and environmentally friendly, offering a rapid application process to any thickness with fast curing for quicker project turnaround. Ideal for exposed surfaces, it ensures superior flexibility, seamless protection, and reliable performance across multiple substrates in demanding environments.
Hydrothane HP is spray applied only, by trained and approved applicators using high pressure heated multi-component equipment; the detailed procedure is in the MATEX method statement.
Summary of the method in the Hydrothane Hp Technical Data Sheet. Always follow the full TDS on site.
| Standard | Title | Referenced for |
|---|---|---|
| ASTM D638 | Standard Test Method for Tensile Properties of Plastics | Tensile properties (tensile strength ≥ 16 MPa) |
| ASTM D2240 | Standard Test Method for Rubber Property—Durometer Hardness | Shore D hardness (45 ± 5) |
| ISO 868 | Plastics and ebonite — Determination of indentation hardness by means of a durometer (Shore hardness) | Shore D hardness |
| ISO 4662 | Rubber, vulcanized or thermoplastic — Determination of rebound resilience | Rebound resilience (≥ 32) |
| ASTM D4060 | Standard Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser | Taber abrasion (<8 mg CS17, <80 mg H18, 1000 cycles) |
| ASTM D4541 | Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers | Pull-off strength on concrete (≥ 1.5 N/mm²) |
Standards and test methods as referenced in the Hydrothane Hp Technical Data Sheet. Values in the TDS are typical laboratory results under standard conditions.
Only with high pressure heated multi-component spray equipment feeding an impingement spray gun, and only by trained and approved applicators. The mixing ratio is 1:1 by volume and spraying material temperature is 65°C to 75°C.
Approximately 1–1.1 kg per m² at 1 mm thickness. The coverage rate is approximate and subject to site conditions.
Tack free time is 10–20 seconds at 20°C. It is walkable after 1 hour, takes mechanical load after 2 hours and chemical load after 12–24 hours.
Application temperature is -5°C to +50°C. Below 15°C ambient, the chemical drums should be pre-heated with band heaters to 30 to 40°C.
It is supplied in 40 or 425 kg sets. Shelf life is 12 months from production in unopened original packing stored dry at 10°C to 30°C, away from direct sunlight and high humidity.