HYDROCRYL 450 is a high-build, elastomeric, single-component liquid applied waterproofing membrane based on advanced acrylic resins, offering excellent elasticity, durability, and adhesion to most substrates. Designed for horizontal and vertical surfaces, it resists ultraviolet rays and forms a semi-gloss, water-based, low-odor, and environmentally friendly coating. HYDROCRYL 450 reduces heating through its reflective features and can be manufactured in custom colors. Highly elastomeric with superior crack-bridging capabilities, it provides long-lasting protection against chloride and sulphate ions, making it ideal for roofs, hangars, factories, stores, and malls in harsh climatic conditions.
Hydrocryl 450 is a ready-to-use single-component membrane for horizontal and vertical surfaces, applied in a minimum of two coats.
Summary of the method in the Hydrocryl 450 Technical Data Sheet. Always follow the full TDS on site.
| Standard | Title | Referenced for |
|---|---|---|
| ASTM D2240 | Standard Test Method for Rubber Property—Durometer Hardness | Shore A hardness (50) |
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Tensile strength (1.2 N/mm²) and elongation (>500%) |
| BS EN 12390 | Testing hardened concrete | Water penetration (nil) |
| DIN 1048 | Testing methods for concrete (Prüfverfahren für Beton) | Resistance to hydrostatic pressure (>1.5 bar) |
| EN 14891 | Liquid applied water impermeable products for use beneath ceramic tiling bonded with adhesives — Requirements, test methods, assessment and verification of constancy of performance, classification and marking | Listed in the TDS |
| ASTM C1305 | Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane | Listed in the TDS |
Standards and test methods as referenced in the Hydrocryl 450 Technical Data Sheet. Values in the TDS are typical laboratory results under standard conditions.
Hydrocryl 450 is used for external waterproofing of roofs, hangars and factories on floors and walls, as a reflective layer on metal sheds, under ceramic coverings in showers and bathrooms, as a top coat over PU foam roofing and EIFS, and on cold stores.
Apply at 1.3 kg/m² per coat (500 micron), with a minimum of two coats. Coverage varies with site conditions.
The service temperature is +5°C to +75°C. It is touch dry in 8 hours and reaches full properties after 7 days.
The TDS lists resistance to diluted acid, petrol, alkali and oil, and good resistance to chloride and sulphate ions. It should not be subjected to permanent water immersion.
It is supplied in 20 kg plastic pails and has a shelf life of up to 12 months when stored in a covered, cool, dry place away from direct sunlight, heat and high humidity.