HYDROCEM 2K is a two-component, acrylic-modified flexible cementitious waterproofing coating, specially designed for protecting water-retaining structures. It consists of selected cements, bonding agents, fillers, and a water-based synthetic acrylic co-polymer. When mixed, HYDROCEM 2K forms a workable slurry that adheres strongly to concrete and masonry surfaces, applied horizontally or vertically. Once cured, it creates a durable, flexible waterproof layer resistant to chloride and sulphate attacks. It offers excellent chemical resistance, UV durability, crack-bridging ability, and is safe for contact with potable water, making it ideal for demanding environments.
Hydrocem 2K is a pre-measured two-component kit mixed on site and brushed on in at least two coats.
Summary of the method in the Hydrocem 2k Technical Data Sheet. Always follow the full TDS on site.
| Standard | Title | Referenced for |
|---|---|---|
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Elongation up to 20% (unbonded); tensile strength >1.0 N/mm² |
| ASTM D2240 | Standard Test Method for Rubber Property—Durometer Hardness | Shore A hardness 60 |
| BS 6920 | Suitability of non-metallic materials and products for use in contact with water intended for human consumption with regard to their effect on the quality of the water | Toxicity: non-toxic |
| EN 14891 | Liquid applied water impermeable products for use beneath ceramic tiling bonded with adhesives — Requirements, test methods, assessment and verification of constancy of performance, classification and marking | Listed in the TDS |
| EN 1504-2 | Products and systems for the protection and repair of concrete structures — Surface protection systems for concrete | Listed in the TDS |
| ASTM C836 | Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course | Listed in the TDS |
| ASTM E96 | Standard Test Methods for Water Vapor Transmission of Materials | Listed in the TDS |
Standards and test methods as referenced in the Hydrocem 2k Technical Data Sheet. Values in the TDS are typical laboratory results under standard conditions.
The TDS describes it as non-toxic and suitable for drinking water, with a non-toxic result under BS 6920. Before using a drinking water tank, wash the applied coat thoroughly with plenty of water while scrubbing with a sponge.
Approximately 8.5-9.0 square meters per 30 kg kit at 2.0 mm thickness. A build-up of 3.4 kg/m² gives a 2.00 mm membrane.
It is rated for positive side water pressure up to 5 bar, tested per BS EN 12390 part 8.
Apply between +5°C and +35°C. Service temperature is -5°C to +80°C.
At least two coats, applied in opposite directions, with no more than 1 mm per coat. The recoating interval is 4-8 hours and drying time is 8 hours.