    HYDROCEM 2K FLEX is a high-performance, two-component, acrylic-modified flexible cementitious waterproofing coating designed for water-retaining structures. It consists of special cements, bonding agents, fillers, additives, and a water-based synthetic acrylic co-polymer. HYDROCEM 2K FLEX is supplied pre-packaged for easy on-site mixing with a slow-speed drill and paddle. It can be applied by brush, trowel, or spray, offering excellent mechanical strength, flexibility, and chemical resistance. It bonds securely to green or damp concrete, is vapor permeable, UV resistant, and suitable for potable water applications, making it ideal for both new and existing structures.

    Technical data:
    • Appearance : Comp.A: grey or white powder , Comp. B: white liquid
    • Workable time : >45 minutes @ 25°C
    • Application Temperature : 5°C to 35°C
    • Service Temperature : -5°C to 80°C
    • Drying time : 8 hours
    • Recoating interval : 4-8 hours
    • Coverage : 8.0 – 8.5 m² per bag @ 2mm thickness
    • Packaging : 15 & 30 kg kit.

    How to Apply Hydrocem 2k flex

    Hydrocem 2K Flex is a pre-measured two-component kit mixed on site and brushed on in at least two coats.

    1. Prepare the substrate. Surfaces must be sound, clean and free from loose material, efflorescence, laitance, curing compounds, dirt, oil and grease, and concrete must be cured for at least 14 days. Level and smooth the surface, remove hard laitance by captive or sand blasting, repair degraded concrete, and treat exposed reinforcement with Lavafer.
    2. Form fillets and treat cracks. Create a 45° fillet at wall-floor junctions with Lavarep F40 or Lavarep F60. Fill superficial cracks with cementitious repair mortar or a paste of Hydrocem 2K Flex, fill dynamic penetrating cracks with flexible injection resins, and plug concentrated seepage with Hydroplug.
    3. Pre-wet the surface. Saturate the substrate with clean water until a saturated surface dry (SSD) condition is reached.
    4. Mix. Pour the liquid (part B) into the container and slowly add the powder (part A). Mix with a low-speed mixer (300-400 rpm) and paddle for 3-5 minutes until homogeneous and lump free, then leave for 4 minutes to release entrapped air.
    5. Treat joints in tanks and pools. For internal waterproofing of water tanks and swimming pools, fix Hydrojoint Tape at joints and penetrations. Brush a strip of Hydrocem 2K Flex 75 mm wider than the tape on both sides, embed the tape with a steel spatula, and let the strip dry before coating the whole area.
    6. Apply the coats. Brush on at least two coats in opposite directions, no more than 1 mm per coat, letting the first harden sufficiently before the second. A build-up of 3.4 kg/m² gives a 2.00 mm membrane. Where movement or cracking is expected, embed reinforcing fiber mesh in the first coat while wet and fully cover it with the second.
    7. Protect, cure and clean. Protect from rain and water spillage for the first 24 hours and shade the work area in peak summer heat. In drinking water tanks, wash and sponge-scrub the coating thoroughly before use. Clean tools with water before the product hardens.

    Summary of the method in the Hydrocem 2k flex Technical Data Sheet. Always follow the full TDS on site.

    Standards & Test Methods

    StandardTitleReferenced for
    ASTM D412Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—TensionElongation 40% (unbonded); tensile strength >1.50 N/mm²
    ASTM D2240Standard Test Method for Rubber Property—Durometer HardnessShore A hardness 45±5
    BS 6920Suitability of non-metallic materials and products for use in contact with water intended for human consumption with regard to their effect on the quality of the waterToxicity: non-toxic
    EN 14891Liquid applied water impermeable products for use beneath ceramic tiling bonded with adhesives — Requirements, test methods, assessment and verification of constancy of performance, classification and markingListed in the TDS
    EN 1504-2Products and systems for the protection and repair of concrete structures — Surface protection systems for concreteListed in the TDS
    ASTM C836Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing CourseListed in the TDS
    ASTM E96Standard Test Methods for Water Vapor Transmission of MaterialsListed in the TDS

    Standards and test methods as referenced in the Hydrocem 2k flex Technical Data Sheet. Values in the TDS are typical laboratory results under standard conditions.

    Frequently Asked Questions

    Is Hydrocem 2K Flex safe for drinking water tanks?

    The TDS describes it as non-toxic and suitable for drinking water, with a non-toxic result under BS 6920. Wash the cured coat thoroughly with plenty of water while scrubbing with a sponge before using the tank.

    What is the crack bridging and elongation of Hydrocem 2K Flex?

    Crack bridging at breakage is >1.0 mm (BS EN 1062) and elongation is 40% unbonded (ASTM D412).

    What is the coverage of Hydrocem 2K Flex?

    The TDS gives approximately 8.0-8.5 square meters per bag at 2.0 mm thickness, and states that a build-up of 3.4 kg/m² gives a 2.00 mm membrane.

    Can Hydrocem 2K Flex be applied over existing tiles?

    Yes. The TDS lists maintenance application on top of existing ceramic or marble flooring as a waterproof coating before fixing new tiles. Fix the new tiles with a tile adhesive of a similar degree of flexibility.

    What packaging is Hydrocem 2K Flex available in?

    It is supplied as 15 kg and 30 kg kits (powder bag plus liquid jerrycan). Shelf life is 12 months from production in unopened original packing.