HYDROCEM 1K is a flexible, single-component cementitious waterproofing slurry designed for both internal and external applications. It forms a durable, highly bonded waterproofing layer that withstands positive water pressure up to 1.5 bars. Ideal for negative and positive waterproofing requirements, HYDROCEM 1K offers excellent mechanical strength, abrasion resistance, and chemical durability. It adheres strongly to concrete and masonry surfaces and can be applied easily over damp substrates. Once cured, it creates a flexible, seamless layer compatible with various coatings, tile adhesives, and toppings. HYDROCEM 1K provides a low-maintenance, long-lasting waterproofing solution for a wide range of building projects.
Hydrocem 1K is mixed with water on site and applied in two coats, green on green, by trowel, brush or spray machine.
Summary of the method in the Hydrocem 1k Technical Data Sheet. Always follow the full TDS on site.
| Standard | Title | Referenced for |
|---|---|---|
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Tensile strength 3.25 N/mm² |
| EN 1504-9 | Products and systems for the protection and repair of concrete structures — General principles for the use of products and systems | Listed in the TDS |
| EN 14891 | Liquid applied water impermeable products for use beneath ceramic tiling bonded with adhesives — Requirements, test methods, assessment and verification of constancy of performance, classification and marking | Listed in the TDS |
| EN 1062 | Paints and varnishes — Coating materials and coating systems for exterior masonry and concrete | Listed in the TDS |
| EN ISO 7783 | Paints and varnishes — Determination of water-vapour transmission properties — Cup method | Listed in the TDS |
| BS 6920 | Suitability of non-metallic materials and products for use in contact with water intended for human consumption with regard to their effect on the quality of the water | Listed in the TDS |
| ASTM E96 | Standard Test Methods for Water Vapor Transmission of Materials | Listed in the TDS |
Standards and test methods as referenced in the Hydrocem 1k Technical Data Sheet. Values in the TDS are typical laboratory results under standard conditions.
When cured, Hydrocem 1K can withstand positive water pressure up to 1.50 bars and passed resistance to 1.50 bar pressure per BS EN 12390-8. It is suitable for both negative and positive side waterproofing.
The TDS states 7.0-7.5 square meters per 25 kg bag at 2.00 mm thickness. The application section specifies 1.9 kg/m² per coat, with two coats (3.8 kg/m²) giving a 2.00 mm dry film.
Two coats are generally recommended, the second applied green on green within 5 to 8 hours and perpendicular to the first. A third coat is recommended where the membrane will face water under pressure.
Workable time after mixing is 45 minutes at 25°C. The TDS advises mixing only as much as can be used within 30 minutes and stirring frequently.
Uses listed in the TDS include swimming pools and water reservoirs before tiling, water tanks and concrete pipes, facade damp proofing, vapor barrier under cladding, shafts, basements, foundations, bathrooms, kitchens and lift pits.