MATEX
Quick Contact
X

    Navigation
    Close menu
    Theme Color
    Light Dark

    Waterproofing

    Hydrobit RBE water based rubberized cold applied bituminous coating by MATEX

    Hydrobit Rbe

    Water Based Rubberized Cold Applied Bituminous Coating

    HYDROBIT RBE is a cold-applied, water-based, non-fibrated bituminous coating designed for reliable waterproofing and surface protection. It combines selected bitumen with special additives, creating an easy-to-apply emulsion that dries into a firm, seamless, and flexible membrane. HYDROBIT RBE is ideal for protecting concrete, asphalt, metal, roofing felt, and similar substrates. It is vapor permeable, allowing surfaces to breathe while offering excellent resistance to chloride penetration, mild acids, and alkalis. Solvent-free, asbestos-free, and easy to apply even on damp surfaces, it ensures durable protection without compromising on flexibility. Compatible with all bituminous products, it is perfect for general waterproofing needs.

    Technical data:
    • Color/Appearance : Dark brown liquid
    • Service Temperature : -10°C to 85°C
    • Drying time : 4 hours at 35°C
    • Overcoating time : 14 hours at 35°C
    • Application Temperature : 5°C to 55°C
    • Coverage : 3 to 5 m² per liter
    • Packaging : 20 liter pail and 200 liter drum

    How to Apply Hydrobit Rbe

    Hydrobit RBE is a ready-to-use water based rubberized bitumen emulsion, normally applied in two coats by roller, brush, trowel or spray.

    1. Prepare the surface. All surfaces should be sound, clean, dry and free from loose material, efflorescence, laitance, curing compounds, dirt, oil and grease. Cut and reseal blisters in asphalt or roofing and remove loose chippings. Old concrete and steel must be structurally sound.
    2. Prime porous surfaces. Prime porous surfaces such as concrete and fiber reinforced cement with Hydrobit RBE diluted 1:2 with clean water.
    3. Mix. Hydrobit RBE is a single-component, ready-to-use emulsion. Shake the barrel well to mix any settled material before application.
    4. Apply the first coat. Apply by roller, trowel, brush or spray at 3 to 5 m² per liter per coat. It may be applied to damp but not wet surfaces; dampen brushes before and during use, and in hot, dry weather dampen the surface.
    5. Apply the second coat. Once the first coat is completely dry, apply the second coat at right angles to the first to avoid air bubbles. Two coats are recommended for roller or brush application.
    6. Sand blinding (optional). To provide a key for tiles on screed or plaster, or protection against foot traffic, broadcast clean sand onto the second coat while it is still tacky.
    7. Backfill below-ground work. On footings, Hydrobit RBE can be applied to green concrete immediately after removing the shutter, acting as a curing membrane. Backfill only once the final coat is totally dry, without damaging the coating.
    8. Clean tools. Clean all tools with clean water before the product hardens.

    Summary of the method in the Hydrobit Rbe Technical Data Sheet. Always follow the full TDS on site.

    Standards & Test Methods

    StandardTitleReferenced for
    ASTM D1187Standard Test Methods for Asphalt-Base Emulsions for Use as Protective Coatings for MetalListed in the TDS
    ASTM D2939Standard Test Methods for Emulsified Bitumens Used as Protective CoatingsListed in the TDS
    ASTM C309Standard Specification for Liquid Membrane-Forming Compounds for Curing ConcreteListed in the TDS
    BS 8102Code of practice for protection of below ground structures against water ingressListed in the TDS

    Standards and test methods as referenced in the Hydrobit Rbe Technical Data Sheet. Values in the TDS are typical laboratory results under standard conditions.

    Frequently Asked Questions

    What is the coverage of Hydrobit RBE?

    Hydrobit RBE covers 3 to 5 m² per liter per coat. Two coats are recommended for roller or brush application.

    What are the drying and overcoating times of Hydrobit RBE?

    Per the TDS, drying time is 4 hours at 35°C and over coating time is 14 hours at 35°C. Each coat must be completely dry before the next is applied.

    What is the service temperature of Hydrobit RBE?

    The service temperature is -10°C to +85°C, and the application temperature is +5 to +55°C.

    Can Hydrobit RBE be applied on damp concrete?

    Yes, Hydrobit RBE may be applied to damp but not wet surfaces. On footings it can be applied to green concrete immediately after removing the shutter, where it also acts as a curing membrane.

    What packaging is Hydrobit RBE available in?

    Hydrobit RBE is available in 20 liter pails and 200 liter barrels, with a shelf life of 12 months from production in unopened original packing stored dry and away from direct sunlight.